Innovation


Intense air preheating about 100-200°C below furnace temperature.
Maximum furnace temperature: 1000°C (1300°C special design)
Air excess: min 10% (below 800°C) min 5% (above 800°C)
Regenerated waste gases: about 80% of total POC (products of combustion)
Working mode:
- From ambient temp-up to 1000°C à → regenerative air preheating (100% hot air)
In case of special design (up to 1300°C of process temperature):
- From ambient temperature to 750°C à → cold air operation
- Above 750°C à → regenerative air preheating (100% hot air)
Combustion mode:
- Low NOx flame below 800 °C
- Flameless for ultra-low NOx (only above 800°C)
Air preheating efficiency:
TRGS 2, TRGS 4
TRGS 6, TRGS 8