Environment
NOX emissions: 70 mg/Nm3 @ 3% O2 for Natural Gas
The emissions are referred to these operating conditions:
- Air excess 5%
- Air temperature ≤ 450°C
- Furnace temperature ≤ 1250°C
- Burner load ≥ 80%
(The reported value is the expected one. The guaranteed value will be fixed on a case by case basis according to the furnace type and the specific operating conditions.)