Innovation
Standard features include:
- Continuous measurement by volume percent (%) concentration of four gases species (O2, CO, CO2 and H2).
- High performance sample gas dust filtration system (removing >99.999% of particles with a diameter >0.1 micron)
- Built-in automated gas probe purge control system with user configurable purge duration and interval
- High availability, uptime and low maintenance requirements
- User friendly and full featured touch screen HMI
- Built-in auto detection/diagnostic features (alarming output signals to plant automation system)
- All operational functions of analyzer are controlled and monitored by a software controller in the NextGen® analyzer computer server. Functional parameters of the analyzer are also configurable by the user through the control system